1 available control table entries, 2 select button, 3 add button – Allied Telesis AT-VIEW PLUS 3.1 DEVICE MANAGER User Manual
Page 97: Select button, Add button

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGER
7.3.3.1 Available Control Table Entries
This table shows all control table entries configured on the target RMON agent. Data displayed
in the RMON History window is collected using the selected control table entry. Here you can
create a new entry, or modify or remove an existing entry. By default, the topmost entry is
automatically selected.
The Control table is not automatically updated. To see the latest information, click the Refresh
button.
The table has the following columns:
Index
The index number used to identify this entry.
Data Source
The index of the RMON interface which collects history samples for the entry.
Request Buckets
The number of values which you asked the RMON agent to store.
Granted Buckets
The number of values the RMON agent allows you to store.
Sampling Interval
The time interval at which the RMON agent collects data.
Status
The status of the control entry.
Owner
The owner (creator) of the control entry.
7.3.3.2 Select Button
: changes the control entry displayed in the History window. To change the control entry
displayed, select an entry in the table, then click the Select button. Data collected by the selected
entry is displayed on other tabs thereafter.
Note
- To display changes to the current entry, or to display a new entry with the same index
number as a previously removed entry, be sure to select the current entry. Otherwise, the changes
will not take effect on the other tabs.
7.3.3.3 Add Button
: adds a new entry to the RMON History control table. When you click this button, the Add
Control Table Entry dialog box appears. Enter the following parameters, then click OK to create
an entry.
PN 613-50664-00 Rev B
Page 97 of 118