The components of the Plot Chart tab are discussed below.

6.2.1 Graph

The left half of the window contains the graph showing the values of the selected variables. The
vertical (Y) axis shows the values and the horizontal (X) axis shows time. New values are plotted
when AT-View Plus Device Manager gets them, at the predefined polling interval.

The scale of the X-axis is automatically adjusted according to the number of values plotted. The
X-axis can display a maximum of the latest 20 values. The rightmost point is the most recent.

Each variable is plotted in a different color and shape. A list of the variables on the graph and
their shapes and colors is displayed between the graph and the variable table.

By placing the mouse cursor on the plotted dot on the graph, you can see the exact values
(coordinates) of the variable. For example, when you move the cursor onto the 10th point on the
X-axis which has a value of 100, the numbers "(10,100)" are displayed.

6.2.2 MIB Variable Table

The right half of the window is the table of variables suitable for graph display. Each entry has a
checkbox. Only checked variables are plotted on the graph.

Assume that you selected four variables to display. If one of the variables has very large values,
for instance 1000000, and the other variables have low values, for instance approximately 100,
the vertical axis is automatically scaled to accomodate the largest variable. In this situation, you
can see only the largest variable because the scale of the vertical axis is too large for other three
smaller variables. To see smaller variables, uncheck the largest variable temporarily.

Note

- SNMPv3: Depending on the READ VIEW access settings of the User Account Name

used, there is a possibility that some MIB variables will not be displayed in this table.

6.2.3 Select All Button

: checks all variables. Clicking this button causes all variables to be plotted on the graph.

6.2.4 Clear Button

: unchecks all variables.

6.2.5 Reverse Button

: flips the states of all checkboxes, that is, unchecks all variables currently selected and checks

all variables currently not selected.

Note

- Displaying many variables at the same time imposes a load on system resources. If you

encounter delay or reduced system performance, reduce the number of variables displayed, or
increase the polling interval. To reduce the number of variables, uncheck some variables in the