2 add/modify traffic class – Allied Telesis AlliedView-EMS 4.0.2 QoS-Manager User Manual
Page 133

AlliedView™-EMS 4.0.2 QoS Manager User’s Guide
Page 133 of 146
Flow Groups
List of the Flow Groups associated with this Traffic
Class
6.9.3.2 Add/Modify Traffic Class
Property Name Description
Valid Values
Traffic Class ID
(cannot be
modified)
Specifies the unique identifier for
this Traffic Class.
Range: 0-511
Description
Specifies a brief description of the
Traffic Class.
To set this value, enter an
alphanumeric string from 1-15
characters.
Exceed Action Specifies the action to take if the
traffic classes maxbandwidth is
exceeded.
•
drop
•
remark
Exceed Remark
Value
Specifies the DSCP replacement
value for traffic that exceeds the
maxbandwidth.
Range: 0-63
Mark Value
Specifies a replacement value to
write into the DSCP (TOS) field for
all packets.
Range: none, 0-63
Maximum
Bandwidth
Specifies the maximum bandwidth
available to the traffic class.
This can be set by entering a value
using one the following formats:
•
0-16000000 kbps
•
0-16000 Mbps (decimal point
supported)
•
0-16 Gbps (decimal point
supported)
Priority
Specifies the priority value in the
IEEE Standard 802.1p tag control
field that traffic belonging to this
traffic class is assigned.
Range: none, 0-7
Remark Priority Specifies whether the value of the
priority parameter is used to set the
egress queue selection for a frame
and also to replace the 802.1p
priority value in the frame, or just
to select the egress queue for the
frame.
•
yes
•
no
Flow Group List Specifies a list of the Flow Groups
currently assigned to this Traffic
Class.
Select from a list of available Flow
Group IDs.