beautypg.com

Prob, Turn off – Alto-Shaam FRYTECH SERIES ASF-75E User Manual

Page 32

background image

TEMPERATURE VERIFICATION
NOTE:

Because each fryer station is controlled separately, the following procedures must be followed
for every component fryer in multiple-station units.

The temperature of the cooking oil / shortening and the temperature set-point can be verified at any
time.

Press TEMP DISPLAY button once to verify the actual temperature of the cooking oil / shortening.

Press TEMP DISPLAY button twice to verify the set-point temperature.

Press TEMP DISPLAY button three times to return the LED to its previous reading. The LED will also
automatically return to its previous reading after three (3) seconds.

If a defective probe is suspected, measure the temperature of the oil / shortening with a thermometer. Compare
the thermometer reading with the temperature shown in the control to make certain the readings are reasonably
close. If there is a wide discrepancy, perform a complete fryer station shutdown and contact Alto-Shaam service.

ALARM MESSAGES

probable

cause

solution

PROB

Probe open.

Probe wired wrong.

Refer to wiring diagram for correct wiring.
Measure probe in ice water bath for 100 ohms resistance.

HI

Probe shorted.

Hi-limit tripped.

Contact Alto-Shaam service.
Allow frypot to cool and press the OIL HI-LIMIT
RESET

button for three (3) seconds.

DRN

Drain valve interlock.

TURN

OFF

Turn Master Power Switch off, ensure the drain is closed,
and turn Master Power Switch back on.

Electric Fryer Operation & Care Manual • 30

O P E R A T I O N

B A S I C C O N T R O L T R O U B L E S H O O T I N G