Alto-Shaam FRYTECH SERIES ASF-75E User Manual
Page 17

Electric Fryer Operation & Care Manual • 15
O P E R A T I O N
NOTE:
Perform an initial Boil-Out to clean and
sanitize the fryer station before operating.
1.
Service is to be performed by an authorized
Alto-Shaam service agent.
2.
Ensure all local electrical codes, fire codes, and all
other requirements such as hood installation have
been met in the process of installation.
NOTE:
Because each fryer station is controlled
separately, the following procedures must
be followed for every component fryer in
multiple-station units.
3.
Open front access door and ensure drain valve is
in the “CLOSED” position. The handle should be
rotated clockwise until it stops.
4.
Fill frypot with frying compound as indicated.
(
see
illustration
on
the
oil
/
shortening
requirements
page
)
5.
The Master Power Switch is located behind the front
access door. Turn Master Power Switch “ON.”
6.
Press the ELEMENT HI-LIMIT RESET button.
7.
The
LED
display on the control panel will indicate
“-AS-”
, the software version, and then “C ”.
8.
When the fryer has reached 135°F, the melt cycle is
complete and the LED display on the control panel
will indicate “HEAt”.
9.
When the fryer displays the set-point temperature,
product can be fried.
10.
More detailed operating guidelines along with
information on programming are located within this
manual.
11.
To shut the fryer station down, turn the Master Power
Switch located behind the front access door to the
“OFF”
position.
NOTE:
for
your
protection
The fryer station is
furnished with a hi-limit safety shutoff that will
disengage the control if the frying compound
temperature in the frypot would ever exceed
415°F (213°C). The LED will display “Hi”, the
heat will shut off, the timer will be cancelled,
and a constant alarm will sound. In this event,
allow the frying compound temperature to drop
below 415°F (213°C). Open the front access door
and press the OIL HI-LIMIT RESET button for
a period of 3-seconds to restart the control.
S T A R T U P & G E N E R A L O P E R A T I O N
D A N G E R
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.