Electric Fryer Operation & Care Manual • 9
I N S T A L L A T I O N
An electrical wiring diagram is located in the front
access door of the fryer. The fryer must be installed by a
qualified electrician. This appliance must be branch circuit
protected with proper ampacities, in accordance with
the wiring diagram located in the fryer. The fryer must
be properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnect the unit must be incorporated into the fixed
wiring in accordance with wiring codes.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific fryer. For supply connections,
locate the wire size posted on the label located on the
electrical control box cover, behind the service panel or
elsewhere listed in this manual.
Before operating the fryer, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufficient protection against potential difference. The
terminal is marked with the following symbol.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
E L E C T R I C A L R E Q U I R E M E N T S
D A N G E R
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
ELECTRICAL - ASF-60E
voltage
phase
cycle
/
hz
amps
kW
awg
208-220
(agcy)
3
60
47.0
17.9 aWg 6
at 208
3
60
45.0
16.2 aWg 6
at 220
3
60
47.6
18.2 aWg 6
240
(agcy)
3
60
43.0
17.9 aWg 6
380-415
at 380
3
50
20.4
15.4 aWg 10
at 415
3
50
25.4
18.3 aWg 10
440-480
(agcy)
3
60
21.8
18.1 aWg 10
at 440
3
60
20.4
15.5 aWg 10
at 480
3
60
22.2
18.5 aWg 10
No cord or plug
ELECTRICAL - ASF-75E
voltage
phase
cycle
/
hz
amps
kW
awg
208-220
(agcy)
3
60
68.2
26.0
AWG 2
at 208
3
60
66.6
24.0
AWG 2
at 220
3
60
70.8
27.0
AWG 2
240
(agcy)
3
60
66.8
27.8
aWg 2
380-415
(agcy)
3
50
38.1
27.5
aWg 6
at 380
3
50
35.2
23.2
aWg 6
at 415
3
50
38.2
27.5
AWG 6
440-480
(agcy)
3
60
31.3
26.0
aWg 8
at 440
3
60
30.7
23.5
AWG 8
at 480
3
60
33.4
27.9
AWG 8
No cord or plug