These troubleshooting charts cover many of the problems that might
arise with the APC KVM Switch. If you have a problem with the APC
KVM Switch, refer to these charts first. There may be a simple solution
that you are overlooking.

6.3 Troubleshooting

Symptom

Action

No status light

Verify unit is turned on. Check power cable. If status

light still does not light, turn off the unit and check

the fuse located under the power cord connector. If

the problem persists, contact Technical Support.

Red status LED lit

Internal unit failure. Contact Technical Support.

Green channel LED not lit

Verify that the computer is powered on. Check the

cabling between your computer and the APC KVM

Switch. Verify that a keyboard works when plugged

directly into your computer. If the problem persists,

contact Technical Support.