beautypg.com

Cable connections to other devices – Asante Technologies 2072 User Manual

Page 13

background image

Page 12

AsantéHub 2072 Network Management Module Installation Guide

Cable

Connections to

Other Devices

The NMM’s front panel has two connections (out-of-band) that
provide attachment to other hardware devices such as PCs, Macs,
or dial-up modems:

AsantéView Management System (AMS) Link

RS232 connector

AMS Link

The AMS Link specifically provides the following types of device
connections:

PC and Macintosh connections for Out-of-Band
network management

Hub interconnections for out-of-band (daisy-
chained from one hub to another)

The two AMS Link connectors are RJ-45 ports that provide an
interface to a PC or Macintosh running AsantéView Out-of-Band
management software. You can daisy-chain as many as twelve hubs
via the AMS Link for simultaneous out-of-band management.

Connecting Hubs in an

Out-of-Band Daisy-Chain

To connect hubs in an out-of-band daisy-chain using the AMS Link
connector:

1

Be sure the length of the daisy-chain, from the man-
agement station to the hub furthest away, is less than
2000 feet.

2

Connect a straight-through RJ-45 extension cable (

not

provided in the package) from an AMS Link connector
on the first hub to an AMS Link connector on the sec-
ond hub.

Connect the hubs in a daisy-chain as shown in
Figure 4 on page 13.

3

To enable termination in the Out-of-Band daisy-chain,
set DIP Switch 1

DOWN

(END) on the end hub only.

4

On all other hubs in the chain, set DIP Switch 1

UP

(THROUGH).