beautypg.com

American Dryer Corp. ADS-464 User Manual

Page 66

background image

62

- Open the UNLOAD doors and locate the UNLOAD doors switch actuator.

- Cycle the switch by hand and have someone watch PLC (Programmable Logic Controller) input indicator

#7. It should go “ON” when the switch is down. Do the associated L.E.D.’s (light emitting diode) come
“ON” when switch is down?

-

If “YES,” wiring is OK

- Check switch placement and door actuation

-

If “NO,” check associated:

- Switch and wiring

- Check wiring back to the tumbler junction box

- Check wiring back to the rear controls

- Check PLC (Programmable Logic Controller)

-

Refer to blueprints: Main Electrical Panel Diagram

- Tumbler junction box diagram

- Rare panel controls wiring diagram

-

Re-test; verify that the signal is operational

4.0 “DRUM FAULT MESSAGE” Malfuntion

a) PROBABLE CAUSES;

1.

Stop Motion Detector module or sensor

2.

Wiring back to main electrical enclosure

b) PROBABLE SOLUTIONS;

1.

Open the Main Electrical Enclosure locate input #0, 10 on the PLC (Programmable Logic Controller).
With control voltage “ON” (Green Push-Button), use the pendant to rotate the tumbler. Notice a
L.E.D. (light emitting diode) on as the tumbler is rotating.

- If the L.E.D. if off, refer to section 1a

1a) If the LED is off:

- Check Fuse 2; replace if necessary

- Rotate the tumbler using the pendant control, and adjust the stop

- Does the module’s L.E.D. respond?