beautypg.com

American Dryer Corp. ADS-464 User Manual

Page 59

background image

55

- Check fuse 10’s blown fuse indicator

- Check wiring; refer to ADS-464 Main Panel Wiring Diagram

- Re-Test

7. “DRUM FAULT” Message

PLC (PROGRAMMABLE LOGIC CONTROLLER) MESSAGE “DRUM FAULT”

a. PROBABLE CAUSE;

1.

Stop motion detector module or sensor. With control voltage “ON” (green push-button), use the pendant
control in “LOAD POSITION” to rotate the tumbler.

Note input #0, 10 on the PLC, stop the tumbler and wait for device’s latched relay to de-energize. The
time from when the tumbler stopped to the relay de- energizing should be 15-20 seconds.

- If the de-energizing time is satisfactory, the unit is operating correctly

- Check circiut wiring, and Re-Test (refer to ADS-464 Main Panel Wiring Diagram)

- If the de-energizing time is incorrect:

- Adjust the “time adjust” on the stop motion detector module and re-test

If the input # 0, 10 on the PLC is not on after several rotations of the tumbler:

- Check fuse 2 and replace if necessary.

- Rotate the tumbler using the pendant control in “LOAD POSITION.” Does the module’s L.E.D.

respond?

- If “YES,” adjust the “sense time” until the L.E.D. (light emitting diode) stays on for 15-20 seconds

after tumbler stops, then refer to section 1 above

- If “NO,” check:

- Inductive proximity sensor for damage

- Sensor distance from targets is 3/16’. The proximity sensor is located in the same area as the
tumbler junction box.

- Inductive proximity adjustment

- Tumbler target

- Stop motion detector module

- Circiut wiring; refer to ADS-464 main panel wiring diagram ADS-464 tumbler junction box wiring
diagram