Instruction manual ADM

45

gis

6.2

Draining vented
installations

Some service activities require the appliance to be drained. The procedure is as
follows:
1. Shut down the appliance by setting the ON/OFF switch on the control panel

to position 0.

2. Isolate the water heater from the power supply by putting the isolator

between the appliance and the mains power supply to position 0.

3. Shut off the gas supply (10).
4. Close the stop valve (11) in the hot water pipe.
5. Close the stop valve (4) between the cold water head tank and the cold

water inlet.

6. Open the drain valve (9).
7. Bleed the appliance (or installation) so that it drains completely.