beautypg.com

3 "gas data") – A.O. Smith ADM - 80 User Manual

Page 20

background image

Installation

20

Instruction manual ADM

3

is

3.4.3

Gas data

Gas data

Description II

2H3+

Unit

ADM
40

ADM
50

ADM
60

ADM
80

ADM
90

ADM
115

ADM
135

Gas category 2H: General
Orifice diameter

mm

3.20

3.20

3.10

2.95

3.20

3.20

3.90

(1) = Blank plate
(2) = Burner pressure regulator
(3) = High/low regulator

1, 2 or 3

2

2

2

2

2

2

2

Gas category G20 - 20 mbar
Nominal load (gross calorific value) kW

42.2

56.5

66.4

82.5

98.3

126.6

143.4

Nominal output

kW

32.3

42.8

50.2

62.4

74.3

95.8

109.8

Supply pressure

mbar

20

20

20

20

20

20

20

Burner pressure

mbar

8.5

8.5

8.5

8.5

8.5

8.5

11.3

Gas consumption

(*)

m

3

/h

4.0

5.4

6.3

7.9

9.4

12.1

13.7

Gas category 3+: General
Orifice diameter

mm

1.70

1.70

1.70

1.50

1.70

1.70

2.25

(1) = Blank plate
(2) = Burner pressure regulator
(3) = High-low control

1, 2 or 3

1

1

1

1

1

1

3

Gas category G30 - 30 mbar
Nominal load (gross calorific value) kW

41.6

55.3

68.2

80.7

96.1

123.5

138.4

Nominal output

kW

32.6

42.8

52.8

62.6

74.5

95.8

108.5

Supply pressure

mbar

30

30

30

30

30

30

30

Burner pressure

(†)

mbar

-

-

-

-

-

-

-

Gas consumption

(*)

kg/h

3.0

4.0

5.0

5.9

7.0

9.0

10.1

Gas category G31 - 37 mbar
Nominal load (gross calorific value) kW

38.4

51.1

63.3

77.7

89.6

113.0

130.1

Nominal output

kW

30.0

39.5

48.9

60.1

69.2

87.4

101.7

Supply pressure

mbar

37

37

37

37

37

37

37

Burner pressure

(†)

mbar

-

-

-

-

-

-

-

Gas consumption

(*)

kg/h

2.7

3.7

4.5

5.6

6.4

8.1

9.3

(*) Based on 1013.25 mbar and 15 °C.
(†) If using a blank plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to

the supply pressure. In practice, however, the burner pressure will be lower.

This manual is related to the following products: