beautypg.com

Conversion to a different gas category adm 135 – A.O. Smith ADM - 80 User Manual

Page 36

background image

Conversion to a different gas category

36

Instruction manual ADM

4

is

13. Check the supply pressure and burner pressure

(3.11 "Checking the supply

pressure and burner pressure")

.

14. Remove the sticker showing the new gas category from the conversion kit,

and attach it below the appliance's rating plate. This clearly indicates that the
appliance may no longer be run on the gas for which it was originally
supplied.

15. Start the appliance

(9 "Starting and running")

.

4.2

Conversion to a
different gas
category ADM 135

4.2.1

Introduction

This paragraph describes:

Conversion from LP gas to natural gas

Conversion from natural gas to LP gas

Conversion of gas control

Legend
Only applicable numbers are

mentioned.
1. burner pressure regulator
7. gas control
9. high-low control

1

9

7

IMD-0132 R1

This manual is related to the following products: