Interreach, In-building c overage solution, In-building coverage solution – ADC InterReach 800 ESMR User Manual
Page 8: Typical specifications

6/08
•
102440AE
InterReach
®
In-building
c
overage
Solution
8
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
PHYSICAL SPECIFICATIONS
Digital Host Unit
Dimensions (HxWxD):
Weight:
Color:
Input Voltage:
Output Voltage:
Connectors
RF:
Optical:
DC Output:
Alarm Interface:
Digital Expansion Unit
Dimensions (HxWxD):
Weight:
Color:
Input Voltage:
Output Voltage:
Connectors
Optical:
DC Output:
Alarm Interface:
Digital Remote Unit
Dimensions (HxWxD):
Weight:
Color:
Input Voltage:
Connectors
RF:
Optical:
DC Input:
ENVIRONMENTAL
Operating Temperature:
Storage Temperature:
Water Resistance/
Operator Protection:
AGENCY APPROVALS
FCC Acceptance:
UL Compliance:
“Plenum Rating” (DRU Only):
CUL Compliance:
“Plenum Rating” (DRU Only):
Industry Canada:
QUALITY
Reliability:
3.5" x 19" x 15.25" (89 x 483 x 388 mm)
18.5 lbs (8.4 kg)
Putty White
120 - 240 VAC; 50 - 60 Hz
+48 Vdc nominal
N female
LC
RJ-45
Link OK/NOK LED at each port; unit OK/NOK LED (one per unit)
Two Form C contact closures (for combined minor and combined
major alarms)
Overdrive alarm on DHU
3.5" x 19" x 15.25" (89 x 483 x 388 mm)
18.5 lbs (8.4 kg)
Putty White
120-240 VAC; 50-60 Hz
+48 Vdc nominal
LC
RJ-45
Link OK/NOK LED; OK/NOK LED at each port
2.25" x 7" x 8" (57.15 x 178 x 204 mm)
1.5 lbs (<1 kg)
Putty White
+38 to +40 Vdc
SMA female
LC
RJ-45 (maximum 500 meters with CAT-5)
0° to 50° C
-30° to +70° C
NEMA (National Electrical Manufacturer’s Association) Type 1—
Indoor installation only
ESMR Part 90 - Cell part 22, PCS part 24
UL60950
NEC 300-22; Section C
CUL60950
CEC, Part 1, C22.1; Sections 2-128, 12-101(3) and 12-100
RSS-131
MTBF 80,000 hours; manufactured under ISO 9001 quality system
InterReach
®
In-building Coverage Solution
Typical Specifications