beautypg.com

Operation of controls and gauges, Push – Nilfisk-ALTO ATS 46/53 User Manual

Page 25

background image

American-Lincoln

1-25

ATS 46/53 Battery

FILTER PANEL LATCH (See Figure 21)
The filter panel is located in the hopper filter compartment
and will need to be removed periodically for cleaning or
replacement. Removal of the filter panel requires no tools.
The hopper cover must be opened to gain access to the
filter compartment. The panel filter is held in place by a
hinged frame and latch.

To remove the panel filter, turn the knob counterclockwise
and lift the hinged frame.

The panel filter can now be lifted out and cleaned or re-
placed (see Filter Cleaning instructions in this manual).

To install the replacement panel filter, lower the frame and
turn the knob clockwise to lock the filter in place.

HOPPER TEMP SENSOR (Option) (See Figure 22)
The temp sensor switch monitors the hopper air tempera-
ture near the vac fan. When the temperature of the air
moving through the hopper exceeds 140°F, the switch is
tripped. It turns off the dust control fan and illuminates the
hopper temp light on the warning bank.

The hopper temp sensor can be reset thermal switch which
is located in the hopper filter compartment near the
vacuum fan intake.

When the hopper temp light illuminates, carefully investi-
gate for a possible fire in the hopper.

To reset the temp sensor, press the reset button.

FRONT COVER LATCH (See Figure 23)
The front cover encloses the power source. The cover can
be lifted to allow easy access for service and inspection.

WARNING

Operate Only When Lids, Doors, And Access Panels Are

Securely Closed.

To open the cover, lift the cover latch lever up and turn the
latch ¼ turn. Lift the cover open.

NOTE

The overhead guard option has a safety latch for storing

open cover.

After closing the cover, check it to be certain the latch has
fully engaged and is latched.

NOTE

Side covers can be removed for service.

OPERATION OF CONTROLS AND GAUGES

PUSH

LIFT

AND

TURN

C1722-9706

HOPPER
TEMP
SENSOR

RESET
BUTTON

PUSH

TO

RESET

C1718/9705

FILTER

PANEL
LATCH

LIFT

FRAME TO

REMOVE

FILTER

FILTER

PANEL

TURN LATCH
TO RELEASE

C-1719

C1719

FIGURE 21

C1722

FIGURE 23

C1718