'Load Sequence Timing Array
For I = 1 To 10
'Load the Valve and Timing Array with the valve Settings:
ValveTime(I,1)
=
SiteValve(SiteSequence(I))
'Load the Valve and Timing Array with the number of scans at each setting:
ValveTime(I,2)
=
30
Next
I
'Initialize
Variables
 One=1 
 SeqIndex=1 
 
Count = 1
SeqActiveFlag = True
Site = SiteSequence(SeqIndex)
SiteOutput = Site
Scan
(1,Sec,10,0)
'Instructions to Measure Sensors Inserted Here.
 
 'Set 
valves:
SDMCD16AC
(ValveTime(1,1),1,1)
 
 'Call 
Data
Tables:
CallTable
RawData
CallTable
SiteAvg
Count = Count + 1
 SiteOutput=Site 
 
If SiteAvg.Output(1,1) Then Count = 1
'Reset Count when the
'Site average is output
If
SeqActiveFlag
Then
Site
=
SiteSequence(SeqIndex)
'Show the site number set by
'the Timed Control
If SeqProgrammedFlag = False Then 'Reset the first valve to
'the automatic value
ValveTime(1,1)
=
SiteValve(1)
ValveTime(1,2)
=
30
 TimedControl(10,2,Min,1,SeqIndex,ValveTime,2) 
 TimedControl(10,2,Min,1,SeqIndex,ValveTime,2) 
 SeqProgrammedFlag 
=
True
EndIf
Else
'Set the first valve setting to that for the current Site
'The Site number may be changed by user to switch sites.
ValveTime(1,1)
=
SiteValve(Site)
ValveTime(1,2)
=
0
If SeqProgrammedFlag = True Then 'Set the timed control to only
'use The first value
 TimedControl(1,0,Min,SiteValve(Site),SeqIndex,ValveTime,1) 
 SeqProgrammedFlag 
=
False
EndIf
 EndIf 
 SiteValveCD16 
=
SiteValve(Site)
EndOmit = Count > OmitCounts(Site)
AvgDisable = NOT (EndOmit AND SeqActiveFlag)
 NextScan 
EndProg 