Campbell Scientific SDM-CD8S 8 Channel Solid State DC Control Module User Manual
Page 20
SDM-CD8S 8 Channel Solid State DC Control Module
START FAN CONTROL LOGIC BASED ON HEATER/COOLER
22: If X<=>F (P89)
If heater is on
1: 11--
X
Loc
2: 2
<>
3: 0
F
4: 11
Set high Flag 1
Set flag 1
23: If X<=>F (P89)
If cooler is on
1: 13--
X
Loc
2: 2
<>
3: 0
F
4: 11
Set high Flag 1
Set flag 1
24: If Flag/Port (P91)
If flag 1 is set
1: 11
Do if flag 1 is high
2: 30
Then
Do
Then
25: Z=F (P30)
Put a "1" into fan
1: 1
F
control location
2: 0
Exponent of 10
3: 15--
Z
Loc:
26: Else (P94)
Else, If flag 1 is reset
27: Z=F (P30)
Put a "0" into fan
1: 0
F
control location
2: 0
Exponent of 10
3: 15--
Z Loc :
28: End (P95)
End Then Do/Else/End
29: Do (P86)
Reset flag 1
1: 21
Set low Flag 1
30: End Loop (P95)
End Master Loop
END FAN CONTROL LOGIC BASED ON HEATER/COOLER
START FAN CONTROL LOGIC BASED ON TIME
31: If time is (P92)
If 5 minutes remain
1: 10
minutes into a
out of 15 minute
2: 15
minute
interval
interval,
3: 12
Set high Flag 2
set flag 2
32: If Flag/Port (P91)
If flag 2 is set
1: 12
Do if flag 2 is high
2: 30
Then
Do
Then
33: Beginning of Loop (P87)
Start fan loop
1: 0
Delay
2: 2
Loop
Count
14