2 modem connections using the sc105, Modem connections using the sc105, 3. connections using the sc105 – Campbell Scientific RavenXTV CDMA Sierra Wireless Cellular Modem User Manual
Page 13

RavenXTV CDMA Sierra Wireless Cellular Modem
4.3.2 Modem Connections Using the SC105
.3.2 Modem Connections Using the SC105
The SC105 interface is used to connect the modem to a datalogger’s CS I/O
port, and is recommended for dataloggers with the PakBus operating system.
The SC105 interface is used to connect the modem to a datalogger’s CS I/O
port, and is recommended for dataloggers with the PakBus operating system.
Wiring:
Red
12V (or
switched
12V)
Black G
White Not Used
10873 serial cable
provided with the SC105
SC105 Settings:
CS I/O Mode: SDC Address 7
RS-232 Mode: Modem
Baud Rate: 115.2K or 9600 baud depending on datalogger model
8 data bits, 1 stop bit, no parity
FIGURE 4-3. Connections using the SC105
7