4. Quickstart

4.1 Step 1 — Mount the Sensor

To mount the sensor, do the following.

1. Mount a CM202, CM204, or CM206 crossarm to a tripod or tower.

2. Orient the crossarm north-south, with the CM220 Mount on the north end.

3. Place the 27739 30 inch pole in the bottom of the P2546A.

4. Place the bottom of the 27739 pole in the CM220's u-bolt and tighten the

nuts (see FIGURE 4-1).

5. Use a bubble level to ensure that the anemometer is level.

6. Route the sensor cable along the underside of the crossarm to the tripod or

tower, and to the instrument enclosure.

7. Secure the cable to the 27739 pole, crossarm, and tripod or tower using

cable ties.

FIGURE 4-1. 27739 pole mounted to a crossarm via the CM220