beautypg.com

Installation – Campbell Scientific IRS21 Road Weather User Manual

Page 8

background image

IRS21 Lufft Intelligent Road Surface Sensor

3. Installation

FIGURE 3-1. Core cut for the road sensor.

Hole diameter = 6”
Hole depth = 3”
Saw cut depth = 2”
Saw cut width = 1/2”

Locate the place in the pavement for the sensor. Drill the sensor hole 3” deep,
and clear the drilled hole of all excess material.

Saw cut the road surface for the sensor lead. The cut needs to be extended
beyond the sensor hole to completely clear the sensor hole of excess material.

4