IRS21 Lufft Intelligent Road Surface Sensor
;start irs21 sensor 1
;the polling string to send to the sensor for measurement is strst 1 "&26&41&0D&0A"
;the filter string for the sio4 is fltst 12 "n9Fn1Fn1fn3Fn1Fn3fff"
;the port setup is portset 3 13 3 0 0 9 0
;this sensor is set up for 19.2 kbaud, no parity, 8 data bits, 1 stop bit
;dtr hi to power the interface and puck and rts high for data to logger
1: SDM-SIO4 (P113)
1: 1
Reps
2: 0
Address
3: 3
Send/Receive
Port
3
4: 1027
Command
5: 0022
1st
Parameters
6: 0000
2nd
Parameters
7: 0
Values
per
Rep
8: 1
Loc [ dummy ]
9: 1.0
Mult
10: 0.0
Offset
2: Delay w/Opt Excitation (P22)
1: 1
Ex
Channel
2: 0
Delay W/Ex (0.01 sec units)
3: 250
Delay After Ex (0.01 sec units)
4: 0
mV
Excitation
;rts lo to send data to sensor
3: SDM-SIO4 (P113)
1: 1
Reps
2: 0
Address
3: 3
Send/Receive
Port
3
4: 1027
Command
5: 0010
1st
Parameters
6: 0000
2nd
Parameters
7: 0000
Values
per
Rep
8: 1
Loc [ dummy ]
9: 1.0
Mult
10: 0.0
Offset
;&A
4: SDM-SIO4 (P113)
1: 1
Reps
2: 0
Address
3: 3
Send/Receive
Port
3
4: 1024
Command
5: 0001
1st
Parameters
6: 0000
2nd
Parameters
7: 0
Values
per
Rep
8: 1
Loc [ dummy ]
9: 1.0
Mult
10: 0.0
Offset