beautypg.com

Configuration, 1. factory settings – Campbell Scientific CS450/CS455 Pressure Transducer User Manual

Page 9

background image

CS450/CS455 Pressure Transducer

Overpressure:

2x pressure range

Dry Storage Temperature: -10°

to

80°C

Sensor will be damaged if it is encased in frozen liquid.

CAUTION

Operating Temperature:

to

60°C

Temperature Accuracy: ±0.2°C

Maximum Cable Length:

SDI-12 — one sensor connected to a single port can
communicate up to approximately 457 m (1500 ft).
With 10 sensors connected to a single port,
each sensor can have up to 60 m (200 ft).

RS-232 — 15 m (50 ft).

Cable Type:

5 Conductor, 26 AWG

Hytrel

Jacket

Body Material:

CS450 – 316L Stainless Steel

CS455

Titanium

Element Material:

CS450 – 316L Stainless Steel

CS455

Hastelloy

Top Cone Material: Delrin

Dimensions:

Length 213.36 mm (8.4 in)

Diameter 21.34 mm (0.84 in)

Distance from pressure-sensor interface
(black line etched on housing) to:
End of NPT fitting:

2.86 cm (1.13 in)

End of standard nose cone: 4 cm (1.58 in)
End of weighted nose cone: 11.59 cm (4.56 in)

Weight:

CS450: 0.18 kg (0.40 lb)

CS455: 0.11 kg (0.25 lb)

Cable: 0.421 kg/m (0.283 lb/ft)

* Total ERROR Band (TEB) includes the combined errors due to nonlinearity,
hysteresis, nonrepeatability, and thermal effects over the compensated
temperature range, per ISA S51.1.

** 0.05% FS accuracy not available in the 0 – 2.9 psig range.

3. Configuration

The CS450/CS455 is configured at the factory with default settings:

TABLE 3-1. Factory Settings

SDI-12 Address

0

RS-232 Baud Rate

9600

Pressure/Level Units

PSIG

Temperature Units

Celsius

3