3. In the Start Address field, type in the number of the first input location.

4. In the Number of InLocs field, type in 2 and select OK.

Below is a portion of a CR10X program that measures the CS450/CS455.

The instructions below do not store data in final storage.
Instruction 92, Instruction 77, and processing instructions such as
Instruction 70 are required to store the data permanently.

NOTE

;{CR10X}
;
*Table 1 Program
01: 60

Execution

Interval

(seconds)


1: SDI-12 Recorder (P105)
1: 0

SDI-12

Address

2: 0

Start

Measurement

(aM0!)

3: 1

Port ;this is where the white wire is connected

4: 1

Loc[Data_1

]

5: 1.0

Mult

6: 0.0

Offset


*Table 2 Program
02: 0.000

Execution

Interval

(seconds)


*Table 3 Subroutines

End Program

After Instruction 105 is executed, the input location called “Data_1” will hold
the measured pressure, reported in PSI, and the input location called Data_2
will hold the measured temperature, in degrees Celsius. The results can be
further processed by the datalogger. Note that Port 1 specifies that the SDI-12
data line is to be connected to the Port C1.

7. Maintenance

Campbell Scientific recommends that the CS450/CS455 be factory recalibrated
and checked every 24 months. Before a CS450/CS455 sensor is sent to
Campbell Scientific, the customer must get an RMA (returned material
authorization) and fill out the Declaration of Hazardous Material and
Decontamination form.

The CS450/CS455 has no user-serviceable parts. Cable can be damaged by
abrasion, rodents, sharp objects, twisting, crimping or crushing, and pulling.
Take care during installation and use to avoid cable damage. If a section of
cable is damaged, it is recommended that you send your sensor back to replace
the bale harness assembly.