Edlog program examples, 1 cr10(x), cr510, and cr500 examples, 1 instruction 6 (4-wire full bridge measurement) – Campbell Scientific CS420 and CS425 PDCR 1830-8388 Pressure Transducer User Manual
Page 15: 1 wiring, 2 edlog program

CS420-L and CS425-L Pressure Transducers
7. Edlog Program Examples
7.1 CR10(X), CR510, and CR500 Examples
7.1.1 Instruction 6 (4-Wire Full Bridge Measurement)
7.1.1.1 Wiring
Datalogger
CS420-L/CS425-L
Excitation
E1
Red (Supply +)
Input
H1
Yellow (Output +)
Input
L1
Blue (Output -)
An. Ground
AG
White (Supply -)
G
Clear
(Shield)
The orange and black wires are not used and the ends of these wires should be
taped to prevent shorting.
7.1.1.2 Edlog Program
; Measure one 4-wire DRUCK Sensor.
* Table 1 Program
01: 5
Execution
Interval
(seconds)
1: Full Bridge (P6)
1: 1
Reps
2: 3
25 mV slow range
3: 1
DIFF
channel
4: 1
Excite all reps w/Exchan 1
5: 2500
mV
excitation
6: 1
Loc
[DEPTH_FT]
7: 2.3529 Mult
8: -0.49
Offset
; Every 60 minutes output the array ID, time,
; and average water depth in feet
2: If Time Is (P92)
1: 0
Minutes (seconds --) into
2: 60
Interval (same units as above)
3: 10
Set output flag high (Flag 0)
3: Real Time (P77)
1: 110
Day, Hour/Minute (midnight = 0000)
4: Average (P71)
1: 1
Reps
2: 1
Loc
[DEPTH_FT]
11