beautypg.com

Return codes, Example of data returned by function call, 14 getstatus() – Campbell Scientific BMP5 Direct SDK User Manual

Page 21: Syntax, Parameters, Example of data returned from a cr200

background image

Section 2. SimplePB.DLL Reference

Return Codes

0 = Successful.
-1 = Communication timed out.
-2 = Port is not open.

Example of data returned by function call

PakBusAddress=1;

2.14 GetStatus()

Query the datalogger for its current status.

Syntax

GetStatus(pakbus_address, device_type, return_data, return_data_len)

Parameters

pakbus_address: Integer – The PakBus address of the datalogger.

device_type: Integer – The type of datalogger:

• 1=CR200

• 2=CR10XPB, CR23XPB, CR510PB

• 3=CR1000

• 4=CR3000

• 5=CR800, CR850

return_data: Char – The location in memory where the data returned from the
datalogger exists.

return_data_len: Integer – Number of bytes in the data returned from the
datalogger.

Return Codes

0 = Successful
-1 = Communication timed out
-2 = Port is not open

Example of data returned from a CR200

OS Version: v03A
OS Signature: 43529
Serial Number:
PowerUp Progr:

2-11