beautypg.com

Am16/32a specifications – Campbell Scientific AM16/32A Multiplexer User Manual

Page 9

background image

AM16/32A Relay Analog Multiplexer

FIGURE 1. AM16/32A Relay Multiplexer

3. AM16/32A Specifications

Power*:

Unregulated 12 VDC
Minimum Operating Voltage:

from –55C to +40C = 11.3 VDC;
from +40C to +85C = 11.8 VDC

(See Figure 2 for relay actuation times vs.
temperature and supply voltage.)

Current Drain:

Quiescent: < 210 uA
Active: 6 mA typical in “2 x 32” mode

11 mA typical in “4 x 16” mode

Reset*:

A continuous signal between 3.5 VDC and 16 VDC
holds the AM16/32A in an active state (where a
clock pulse can trigger a channel advance). A
signal voltage < 0.9VDC deactivates the
AM16/32A (clock pulse will not trigger a scan
advance; AM16/32A is also reset).

Clock*:

On the transition from <1.5 V to >3.5 V, a scan
advance is actuated on the leading edge of the clock
signal; clock pulse should be a minimum of 1 ms
wide.

Operational
Temperature:

Standard: -25oC to +50oC
Extended: -55oC to +85oC

Operational
Humidity:


0 - 95%, non-condensing

3