beautypg.com

Campbell Scientific 107-L Temperature Probe User Manual

Page 14

background image

Model 107 Temperature Probe

Standard air temperature measurement heights:

1.25 to 2.0 m (WMO)

2.0 m (EPA)

2.0 m and 10.0 m temperature difference (EPA)

When exposed to sunlight, the 107 should be housed in a 41303-5A or 41303-

5B six-plate solar radiation shield. The louvered construction of the shields

allows air to pass freely through, thereby keeping the probe at or near ambient

temperature. The white shields reflect solar radiation. The 41303-5A attaches

to a crossarm, mast, or user-supplied pipe with a 2.5 to 5.3 cm (1.0 to 2.1 inch)

outer diameter. The 41303-5B attaches to a CM500-series pole or a user-

supplied pole with a 5.1 cm (2.4 inch) outer diameter.

Tools required for installing a radiation shield to a tripod or tower include:

1/2 inch open end wrench

small screw driver provided with datalogger

small Phillips screwdriver

UV resistant cable ties

small pair of diagonal-cutting pliers

FIGURE 7-1. 107 and 41303-5A Radiation Shield on a tripod mast

41303-5A

107

Tripod Mast

or Tower Leg