ACR Electronics 2662 User Manual
Page 74

ACR PART NO.
SCALE
SIZE
CODE IDENT. NO.
18560
A
2686
1:1
Power
Nominal Voltage
Dimensions
Weight
240W (10 A)
Isolated
24Vdc input,
24Vdc output
217 x 87 x 62mm
880g
Input voltage range
24Vdc ± 30%
Output voltage
27.2Vdc +15% -20% at extremes of temperature, load, input
tolerance, etc.
Intermittent output power
Continuous rating +25%, taken for a maximum of 2 minutes
followed by 8 minutes rest.
Transient voltage protection
Meets ISO7637-2 International standard for 24Vdc commercial
vehicles
Electrostatic voltage protection
Meets ISO10605, ISO14892, >8kV contact, 15kV discharge
Output noise
<50mV pk-pk (100mV on 24V units) at continuous load. Meets
CISPR25 and VDE0879-3
Off load current (quiescent current)
<100mA
Power conversion efficiency
Typically: 90% for non-isolated units, 85% for isolated units
Isolation
>400Vrms between input, output and case, on isolated
products only.
Operating temperature
-25°C to +30°C to meet this specification table -30°C to +80°C de
rate linearly to 0A
Storage temperature
-25°C to +100°C
Operating humidity
95% max., non-condensing
Casework
Anodised aluminum, glass filled polycarbonate, dust water and
impact resistance to IP533 (excludes Ddi 24-24 240 which is
ventilated and fitted with a cooling fan
Connections
Four 6.3mm push-on flat blade connectors
Output indicator
Red LED adjacent to output terminals
Mounting method
“Click ‘n’ fit” mounting clip, fitted separately using three-hole
fixing
Safe area protection: Over current
Limited by current sensing circuit
Over heat
Limited by temperature sensing circuit
Transients
Protected by filters and rugged component selection
Catastrophic failure
Protected by internal input and output fuses
Approvals
2004/108/EC The general EMC directive
2006/96/EC The automotive directive
93/68/EEC The CE marking directive
Markings
CE and e marked
Switch
Power On/Off
70