文管中心 發行章, 4. electrical performance, 正式文件,妥善保存 – Samlex America ST1000-148 User Manual
Page 9
8
2-4. Electrical Performance
Specification
Model No.
Item
ST2000-112 ST2000-124 ST2000-148 ST2000-212 ST2000-224 ST2000-248
Continuous Output Power
2000W
Maximum Output Power (3Min.)
2300W
Surge Rating
4000W
Input
Voltage
12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V ± 5%
220 / 230 / 240V ± 3%
Frequency
(Switch Selectable)
50 / 60Hz
Output Waveform
Pure Sine Wave (THD < 3%)
Efficiency
(full
load)
88% 91% 92% 90% 93% 94%
No Load Current Draw
2.6A
1.50A 0.70A 2.3A 1.1A 0.65A
Stand-By Current Draw
0.60A
0.30A 0.2A 0.60A 0.3A 0.15A
Input Voltage Regulation
10.5-15
VDC
21.0-30
VDC
42.0-60
VDC
10.5-15
VDC
21.0-30
VDC
42.0-60
VDC
Input Level Indicator
Red / Orange / Green LED
Load Level Indicator
Failure Indicator
Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over Temperature
Over/Under Input Voltage, AC Input Circuit Breaker
Circuit Breaker
30Amp
Remote Control Unit
CR6 / CR8 Optional
Synchronous AC transfer
YES
Transfer switch
30Amp
25 Amp
Transfer Time
Inverter to utility AC : 8 ~ 10msec. ; Utility AC to inverter : 16 ~ 50 msec
Safety
Meet UL458
------
EMC
EMI Conduction&Radiation
Compliance to FCC Class A
Compliance to EN55022 classA
EMS Immunity
------
Compliance to EN61000-3-2,3
LVD ------
Compliance
to
EN60950-1
e-MARK
------
Compliance to e-13*72/245/ECC,95/54 EC
Operating Temperature Range
0 - 40ɗ
Storage Temperature Range
-30ɗ to 70ɗ
Cooling
Loading controlled cooling fan
Dimensions
433(L)*332(W)*115(H) mm / 17(L)*13(W)*4.53(H) Inch
Weight
11.2 kg / 24.6 Lbs.
Note: The specifications are subject to change without notice.
文管中心
發行章
正式文件,妥善保存