文管中心 發行章 – Samlex America ST1000-148 User Manual
Page 22
21
3-4-2. Connect AC output and AC input wiring to the ST series terminals.
Please take the following information as your reference.
Terminal Wire
color
Wire length / gauge
ST1000&ST1500
ST2000&ST2500
AC
OUTPUT
Line (L)
Black
Within 16 feet / AWG#
14~16
26~32 feet / AWG#
12~14
Within 16 feet / AWG#
10 ~12
26~32 feet / AWG#
8 ~10
Neutral (N)
White
AC INPUT
Line (L)
Brown
Neutral (N)
Blue
Ground
Green / Yellow
or Bare
copper
3-4-3. Please double check and review all connections to ensure
the wires are in correct terminals and the connections are tight.
3-4-4.
Before connecting AC output and AC input terminals of the ST series,
you can either use front compartment cover or a side hole to coil out.
Both AC input and AC output are coiled out from the front compartment
cover when in production. If you want to change the position, you
should open the top cover first, and then switch the wire of the front
compartment cover and the plastic cover of the side of top cover.
文管中心
發行章
正式文件,妥善保存