LBL Lighting LED Illum MO Surf Mag Xfmr 300w 277v/12v User Manual
Important safety information
Installation Instructions for
12 Volt 300 Watt Single Power Feed
Magnetic Surface Mount Transformers
1.3
TRANS-SFM300-SC-LED_
980MRLSFM30SMT-LED
1
G
P
I
:
ENERAL
RODUCT NFORMATION
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
A typical installation is shown. Specific installation must be in
accordance with local electrical codes.
This product may be dimmed only with a low voltage magnetic
dimmer. Using a dimmer not designed for low voltage magnetic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
This product is intended for use with LBL Lighting low voltage LED
lighting systems only.
Read all instructions thoroughly. Read "Important Safety
Information" on next column before proceeding with the
installation.
Important Safety Information
Do not conceal or extend bus bar conductors through a building
wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains
or similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
LED-Illuminated Monorail
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.