LBL Lighting Linear WCF User Manual
Linear (compact fluorescent) wall, Install the fixture

Installation Instructions for
Linear
(Compact Fluorescent)
Wall
1.4
PW5497_PL13
980LINERWCF
G
P
I
:
ENERAL
RODUCT NFORMATION
This product can mount to either a 4" square electrical box with
round plaster ring or an octagon electrical box.
This product is suitable for damp locations.
Install the Fixture
1
Place the ballast inside the electrical box.
Mount the crossbar assembly to the electrical box holes with
the two #8-32 screws provided.
Connect the crossbar to a suitable ground in accordance with
local electrical codes.
CROSSBAR
ASSEMBLY
#8-32 SCREW
BALLAST
ELECTRICAL BOX
Connect the white ballast wire to the neutral power line wire
with a wire nut.
Connect the black ballast wire to the hot power line wire with
a wire nut.
BALLAST
1A
1B
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.