LBL Lighting Cypree Large User Manual
Page 2
2
1D
Gently twist the end of the coaxial cable between thumb and
forefinger.
5
5
Tap the conical connector on a hard surface with the set screw
facing down, so the plate inside drops into place.
SURFACE
PLATE
1E
6
1F
7
Feed and push the coaxial cable into the conical connector.The
coaxial cable will come to a stop point after being inserted
3/4" into the conical connector.
CONICAL CONNECTOR
OUTER WRAPPED
WIRE STOPS HERE
7
INNER WIRE
STOPS HERE
1G
Keep pushing the coaxial cable into the connector while
rotating the connector to ease feeding the inner wire into the
tip of the connector.The outer wrapped wire will start
wrinkling while being inserted another 1/2" into the connector.
WRINKLE ON OUTER
WRAPPED WIRE
8
8
Look into the sight hole on the top of the connector to make
sure that the inner wire is contacting the end of the connector.
Hold the coaxial cable in place and tighten the set screw on tip
of the connector with the provided Allen wrench. Make sure
this set screw connection is tight.
SIGHT HOLE
ALLEN WRENCH
10
9
INNER WIRE
1G
9
10
1H
Firmly tighten the set screw on the conical connector.
11
11
Pull the coaxial cable toward the fixture to smooth the
wrinkles.
1I
12
12