Sample printout:
DATE
TIME
ALTI1
ALTI2
VARIOMETER
Nr.dd.mm.yy
hh:mm
MAX
MAX
MAX
MIN
TIME
1. 03.01.95
11:23
2032
204
1.2
-14.6
00:33
2. 05.01.95
13:45
1892
349
2.5
-12.3
01:26
3. 12.02.95
12:03
1580
89
0.8
-9.8
00:23
4. 03.01.95
11:23
2032
204
1.2
-2.0
01:09
Nr.dd.mm.yy
hh:mm
[m]
[m] [m/s]
[m/s]
hh:mm
Logbook setting mode
All flights in the logbook can be deleted in setting
mode. Cl appears in the MEMO display. The log-
book memory is deleted by pressing the key
for 4 seconds. As soon as the memory has been
deleted, all the segments of the display will flash
briefly and the instrument starts up again.
Logbook option mode
The printer emulation must be given at the first
level of option mode:
EP
Ł Epson FX-80
Ibm
Ł IBM Proprinter
HP
Ł HP Deskjet
These emulations are offered by the majority of
standard dot impact printers.
The width of the printout can be selected at the
second level:
--I I --
Ł condensed mode (double width)
-I I-
Ł normal mode
Operating Instructions FLYTEC 4010
19
Mode SET
Clear MEMO (ALT 4sec.)
Mode OPTION
Emulation
• Epson
• IBM
• HP
Printout width
Norm-Cond
Pilot mame
21 characters
MEMO
MEMO
MEMO 4 Sec.
OPTION
OPTION
➀
➁
➂
ALT 1
ALT 2
CHRONO