9.1.2. System console settings (Only VG3306/3310/3318)
SIP-RG>enable 
SIP-RG #configure 
Enter configuration commands, one per line. End with CNTL/Z 
SIP-RG(config)#regional_id 07 
SIP-RG(config)#exit 
SIP-RG#delete nvram 
This command resets the system with factory defaults. 
All system parameters will revert to their default factory settings. All static 
and dynamic addresses will be removed. 
Reset system with factory defaults, [Y]es or [N]o? Yes 
 
Attention: 
Before Changing the Region ID, the system has to be reset to the default value. Therefore this step 
should be done first. 
The following instruction may keep the IP address unchanged after reset: 
“delete nvram keep_ip” 
9.2. IP
Address
Settings
We recommend using a traditional phone to configure the unit’s parameters, as this is the easiest 
way. The following two sections contain the procedures used to configure the gateway according to 
how you obtain your IP address (Static IP; DHCP or PPPoE). 
 
Every time you set a parameter item and press the “#” key to complete it, a successful setting will be 
confirmed by three equal tones in succession. If your setting is unsuccessful you will be prompted 
with one long tone. 