Fault

Cause

Solution

Who

E02

No thermostatic premixer
available. The supply tem-
perature to the continuous-
flow heater is higher than
55 °C (e. g. due to pre-
warmed water supplied
from a solar water heater).

Install a thermostatic premix-
er in the domestic supply.

Customer

The supply temperature to
the continuous-flow heater
is higher than 55 °C (e. g.
due to pre-warmed water
supplied from a solar water
heater).

The thermostatic premixer
in the domestic supply must
be set accordingly to lower
temperatures.

E03–E04

Temperature sensor
defective

Please contact customer
service.

Customer
Service

E05–E07

Electronic malfunction

Please contact customer
service.

Customer
Service

E08

Frost damage
The water supply sensor
measures a temperature of
≤ 0 °C.

The appliance is defective!
Switch off the water supply
immediately and disconnect
the appliance from then elec-
trical supply (also refer to the
safety instructions). Please
contact customer service.

Customer/
Servicing
expert

E09

Temperature sensor/
electronics defective

Please contact customer
service.

Customer
Service

E10–E11

Bubble detection triggers.

Disconnect the appliance
from the electrical supply.
Open the warm water tap ful-
ly for venting purposes and
flush out the appliance thor-
oughly for 1 minute. Switch
the power back on again.

Customer/
Servicing
expert

E12–E13

Electronic malfunction

Please contact customer
service.

Customer
Service

If the fault could not be eliminated, please call customer service.