Command

Syntax

Default

Notes

Read module type

FE 37
254 55
254 “7”

see table

Reads the module
type.

Set serial number

FE 34 [byte1][byte2]
254 52
[byte1][byte2]
254 “4” [byte1][byte2]

This is a one-
time-use

com-

mand

which

works only on
units

without

factory set serial
numbers.

Read serial number

FE 35
254 53
254 "5"

Reads the two
byte serial num-
bers

of

the

module.

Read version number

FE 36
254 54
254 "6"

Reads

the

firmware

ver-

sion number of
the module.

Enter flow control

FE 3A [full][empty]
254 58 [full][empty]
254 ’:’ [full][empty]

Off

Sets “full” and
“empty”

marks

for the 80 byte
display

buffer.

When

buffer

reaches

[full]

display

will

return 0xFE to
host.

When

buffer

reaches

[empty]

display

will return 0xFF.

Exit flow control

FE 3B
254 59
254 ’;’

Turns off flow
control.