Pinouts for connectors – Clary CMN2400D-PD User Manual
Page 8
Page 8
PINOUTS FOR CONNECTORS
Interface 37 Pin Connector
Pin 1 – Load 1
Pin 21 – +5V
Pin 2 – Load 1 Neutral
Pin 22 – Temp Fail 1, Hi Temp, Shutdown
Pin 3 – Load 2 Neutral
Pin 23 – Load 5
Pin 4 – Load 1 Ground
Pin 24 – Fan Neutral
Pin 5 – Load 2
Pin 25 – Load 5 Ground
Pin 6 – Load 3 Neutral
Pin 26 – Spare 2
Pin 7 – Load 4 Neutral
Pin 27 – Fan Fail 1, OR’d with Fan Fail 2
Pin 8 – Load 2 Ground
Pin 28 – Temp Fail 2, Warm, Alarm
Pin 9 – 5V Return
Pin 29 – Load 6
Pin 10 – Load 3
Pin 30 – Load 6 Ground
Pin 11 – Load 5 Neutral
Pin 31 – Load 7 Ground
Pin 12 – Load 6 Neutral
Pin 32 – Load 8 Ground
Pin 13 – Load 3 Ground
Pin 33 – Fan Fail 2
Pin 14 – 5V Return
Pin 34 – Load 7
Pin 15 – +5V
Pin 35 – Load 8
Pin 16 – Load 4
Pin 36 – Fan Hot
Pin 17 – Load 7 Neutral
Pin 37 – Fan Ground
Pin 18 – Load 8 Neutral
Pin 19 – Load 4 Ground
Pin 20 – Spare 1
AC Input Connector
Pin 1 – 115VAC Line
Pin 2 – 115VAC Neutral
Pin 3 - GND