Ec parts list and lighting instructions, Lighting instructions – Midco EC200 & EC300 User Manual
Page 13
Item Part #
Description Qty
Item Part #
Description Qty
Midco International Inc.
13
8471 38
EC Parts List and Lighting Instructions
1
5236-43
Air Restrictor Pack Includes Orifi ce(.173),
Orifi ce Spring and Hardware
1
2a
5236-20
EC200
Burner
Head
Assembly
1
2b
5236-19
EC300
Burner
Head
Assembly
1
3 8452-44
Bracket
Spacer
2
4
5236-18
EC200/EC300 Flame Rod Assembly
1
5
5236-16
EC200/EC300 Spark Rod Assembly
1
6
5232-25
Flame and Spark Rod Bracket
2
7 8505-94
Flame
Rod
Wire
Assembly
1
8
8505-93
SAEJ2031 Ignition Cable Assembly
1
9a
5236-13
EC200
Blast
Tube
1
9b
5236-14
EC300
Blast
Tube
1
10 8495-04 1/2″
Elbow
1
11a 8437-57
EC200 Motor Blower Assembly
(Includes
Wheel
and
Motor) 1
5236-64
EC200
Blower
Wheel
1
5236-66
EC200
Blower
Motor
1
11b 8437-56
EC300 Motor Blower Assembly
(Includes
Wheel
and
Motor) 1
5236-65
EC300
Blower
Wheel
1
5236-67
EC300
Blower
Motor
1
12 5236-26 EC200/EC300
Washer
EC200
4
EC300
5
13 8487-50 1/2″
Close
Nipple
2
14a
5236-17
EC200
Special
Washer 1
14b
5236-15
EC300
Special
Washer 1
15 8493-67 1/2″
Full
Coupling
1
16 8487-53 1/2″ X 2-1/2″ Long Nipple
1
17 8494-02 1/2″ Tee
1
18 5726-72
R Main Spud- .173 Dr (#17) Orifi ce
1
19 6622-30 Orifi
ce
Spring
1
20 8496-17 1/2″
Square
Plug
1
21 8492-51 3/4″ X 1/2″
Hex
Bushing
1
22a 8419-70
EC200 -Redundant Combination
Slow
Opening
Valve
VR8305K4233 1
22b 8419-75
EC300 Direct Spark Gas Valve
Slow
Opening
Valve
VR8305K4852 1
23a
5236-48
Air
Shutter
Assembly
EC200
1
23b
5236-47
Air
Shutter
Assembly
EC300
1
24 5236-35
Inlet Ring And Air Screen Weldment
EC200
Only
1
25 8480-40 4″ X 4″ Raised Electric Box Cover
1
26
8429-51
Fenwal
2461DSI
Controller 1
27 5236-23A Control
Assembly
(Includes
Control;
Transformer
and
Box)
1
28
8457-47
Strain
Relief
2
Not
Shown
8452-16
Mounting Flange Kit w/ Gasket
8452
48
Flange
Gasket
5734-51
Transformer Repair Kit - EC200/ EC300
7400-20
Wire
Kit
Important: Availability of parts as well as specifi cations are
subject to change without notice. Please consult factory for
item availability. Avoid errors in parts selection, when ordering,
use complete Midco Part number and description. Furnish
burner model number, bill of material number and date code
from the Specifi cation Plate located on the burner.
1. Set operating control to OFF or thermostat below room temperature for at least 30 seconds.
2. Turn manual gas cock knob on combination valve to ON.
3. Turn burner power ON.
4. Set operating control to ON or thermostat to call for heat (there is a 30 second pre-purge).
5. Wait 37 seconds. If burner fails to light, or if burner lights then goes out and system goes into
safety lockout, de-energize the system by setting operating control to OFF or thermostat below
room temperature for at least 30 seconds to reset the system. Then set operating control to ON
or thermostat to call for heat.
TO SHUT OFF
1. Turn manual gas cock knob on combination gas valve to OFF.
2. Turn burner electrical power OFF.
SHOULD OVERHEATING OF THE GAS UTILIZATION EQUIPMENT OCCUR:
1. Shut off the main manual shut-off gas valve to the equipment.
2. DO NOT shut off the power switch to the burner, the equipment pump or blower.
___________________________
Lighting Instructions
Lighting Instructions