MagTek OMTD 99875144 User Manual
Page 21

Section 4. Control Objects
15
Property Name
Access
Type
Description
DataCount
R
LONG Number of enqueued data events at the control. The
default is 0.
DataEventEnabled
R/W
BOOL When TRUE, a DataEvent is delivered as soon as input
data is enqueued. The default is FALSE.
DeviceDescription R
BSTR
String
identifying the device (e.g., MICR Plus).
DeviceEnabled
R/W
BOOL When TRUE, the device is placed in an operational
state. When FALSE, any input is discarded and output
operations are disallowed. The default is FALSE.
DeviceName R
BSTR
Identifies
the
device
(e.g., friendly name of the device).
FreezeEvents R/W
BOOL
When TRUE, the control will not deliver events. The
default is FALSE.
OutputID
R
LONG Holds the identifier of the most recently started
asynchronous output.
PowerNotify R/W
LONG
Contains
the
type power notification selection made by
the application. The default is OPOS_PN_DISABLED.
PowerState R
LONG
Contains
the
current power condition, if it can be
determined. The default is OPOS_PS_UNKNOWN.
ResultCode
R
LONG Result code of the most recently invoked method.
ResultCodeExtended
R
LONG Contains extended result information when ResultCode
is set to OPOS_S_EXTENDED.
ServiceObjectDescription R BSTR
String
identifying the service object supporting the
device and the company that produced it (e.g., “OPOS
Common Service Object, © 1999 MagTek, Inc.”).
ServiceObjectVersion
R
LONG Service object version number.
State R
LONG
Contains
the
current state of the control.
Common Methods
The following methods are common to all OMTD control objects.
LONG Open (BSTR DeviceName)
Call to open a device for subsequent I/O.
When the Open method is successful, it sets the properties Claimed, DeviceEnabled, and
FreezeEvents, as well as descriptions and version numbers of the OPOS software layers (i.e. CO
and SO). Additional class-specific properties may also be initialized.
LONG Close 0
Called to release the device and its resources. If the DeviceEnabled property is TRUE, then the
device is first disabled. If the Claimed property is TRUE, then exclusive access to the device is
first released.