beautypg.com

6 assembling and installing, 3 installation, 7 configuration – Videotec DTWRX User Manual

Page 5

background image

Instruc

tions manual - English - EN

3

6 Assembling and installing

Only specialised personnel should be

allowed to assemble and install the device.

6.3 Installation

Always make the electrical connections

with the power supply disconnected and

the circuit-breaker open.

The receiver includes a safety device that

blocks pump operation at temperatures

lower than -10°C (10°F).

Configure protocol, baud rate and receiver address

via the DS1 dip-switches (Tab. 1, page 3).

Fig. 1

Open the box of the WASPT device.
Connect telemetry lines A and B to connector J9

(WASPT board) as described in the relative manual.

We recommend using a twisted cable with minimum

section of 0.22mm²/0.8in² (AWG24).
If the receiver is connected to one of the head

communication channels RS-485, the line must be

terminated (SW8 column, Tab. 1, page 3).
Insert the DTWRX board in the specific J8 housing

and close the box of the WASPT device.

Fig. 2

Supply power to the device, checking that the

controls function correctly from the start.

7 Configuration

DIP-SWITCH CONFIGURATION (DS1)

Description

SW 1

SW 2

SW 3

SW 4

SW 5

SW 6

SW 7

SW 8

Address

Not available

OFF

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

Protocol and

baud rate

VIDEOTEC MACRO

9600

OFF

OFF

VIDEOTEC MACRO

38400

ON

OFF

PELCO D 2400

OFF

ON

PELCO D 9600

ON

ON

Termination of RS-

485 line

Line terminated

ON

Line not terminated

OFF

Tab. 1