beautypg.com

American Dryer Corp. ML-75V User Manual

Page 27

background image

23

Single-Phase (1Ø) Electrical Connections Leads

Black

+

Positive

White

+

Neutral

Green

+

Ground

or

L2

If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power
cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to
the service breaker panel. In both cases, a strain relief must be installed where the wiring enters
the dryer.

2) 3-Phase (3ø) Wiring Connections/Hookup “Non-Reversing Models Only”

The electrical connections on ALL 3-phase (3ø) gas and steam dryers are made into the rear
service box located at the upper left area of the dryer. Electrical connections for electrically heated
dryers are made in the electric oven area located at the upper rear area of the dryer.

NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.

If local codes permit, power to a gas or steam dryer can be made by the use of a flexible U.L. listed
power cord/pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel. In ALL cases, a strain relief must be installed where the
wiring enters the dryer.