Mlg-75v (gas) mls-75v (steam), Electrical service specifications (per dryer) – American Dryer Corp. ML-75V User Manual
Page 24

20
2. Electrical Service Specifications
a. Gas and Steam Models Only
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
MLG-75V (GAS)
MLS-75V (STEAM)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/ verify
correct breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
50 Hz
60 Hz
Dual Element
Time Delay
120
1ш
2
--
13
*
20
20
208
1ш
2
--
7.6
*
15
15
240
1ш
2
7.8
7
*
15
15
208
3ш
3
--
4.7
*
15
15
240
3ш
3
5.7
4.9
*
15
15
380-400
3ш
4
3
*
15
15
416
3ш
4
3.1
*
15
15
460/480
3ш
3
--
2.8
*
15
15
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes
** 380, 400, and 416 volt dryers are built (4-wire) only. Customer must contact the factory to special order (3-wire)systems.