2. Electrical Service Specifications

a. Gas and Steam Models Only

IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the

factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE
WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or

obligation.

MLG-75V (GAS)

MLS-75V (STEAM)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.

Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed

appliance amp draw data.

B. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/ verify

correct breaker size according to appliance amp draw rating and type of breaker used.

C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

MINIMUM

WIRE SIZE

FUSING

CIRCUIT

BREAKER

50 Hz

60 Hz

Dual Element

Time Delay

120

2

--

13

*

20

20

208

2

--

7.6

*

15

15

240

2

7.8

7

*

15

15

208

3

--

4.7

*

15

15

240

3

5.7

4.9

*

15

15

380-400

4

3

*

15

15

416

4

3.1

*

15

15

460/480

3

--

2.8

*

15

15

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes

** 380, 400, and 416 volt dryers are built (4-wire) only. Customer must contact the factory to special order (3-wire)systems.