Mle-75v (electric), Electrical service specifications (per dryer), 21 b. electric models only – American Dryer Corp. ML-75V User Manual
Page 25

21
b. Electric Models Only
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications of
the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
IMPORTANT: 3-phase (3ø) figures shown are for a 3-wire service only.
MLE-75V (ELECTRIC)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES: A.
B.
C.
208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by
applying either local and/or National Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
KW
208/1ø (60 Hz) 240/1ø (60 Hz) 208/3ø (60 Hz) 240/3ø (50/60 Hz) 380/3ø (50 Hz) 400/3ø (50 Hz) 416/3ø (50 Hz) 460/3ø (60 Hz)