beautypg.com

A.O. Smith BFM 80 User Manual

Page 30

background image

30

Re-instate gas supply

and reset water heater

Water heater in

in operation?

Gas supply

present?

Problem

solved

IONISATION PROBLEMS.
Carry out 3 RESET cycles to make
sure the pilot is provided with gas.
Check gasconnections towards the
pilot burner. Carry out one more
RESET cycle. If no operation is valid
replace the entire PILOT BURNER
assy. RESET water heater after
replacing the PILOT BURNER

Water heater

in operation?

Problem

solved

Check

voltage on

PRIMARY CIRCUIT,

TRANSFORMER

Check

voltage on

SECUNDARY CIRCUIT,

TRANSFORMER

Ensure connections

correct

Problem

solved

Ensure connections

correct. If yes replace

transformer

no

no

no

no

no

yes

yes

yes

yes

yes