beautypg.com

A.O. Smith BFM 80 User Manual

Page 10

background image

10

Description

Unit

BFM 30

BFM 50

BFM 80

DATA NATURAL GAS G 20

Nominal gas inlet pressure

mbar

20

20

20

Burner pressure

mbar

12.5

12.5

12.5

Input

kW

29

47

75

Output to water

kW

27

42

68

Gas consumption*

m3/h

3.0

4.7

7.9

Diameter main injector

m m

2.60

2.50

2.70

Diameter injector ignition burner

m m

0.56 / 0.41

0.56 / 0.41

0.56 / 0.41

Heating time

T=45°C

min

35

25

12

DATA PROPANE/BUTANE G 30 - G 31

G30

G31

G30

G31

G30

G31

Nominal gas inlet pressure

mbar

30

37

30

37

30

37

Input

kW

29

28

46

44

75

71

Gas consumption

kg/h

2.3

2.1

3.6

3.3

5.8

5.3

Diameter main injector

m m

1.45

1.40

1.50

Diameter injector ignition burner

m m

0.25

0.25

0.25

GENERAL

Storage capacity

litre

309

298

253

Number of bar burners

-

3

5

7

Number of anodes

-

2

2

4

Number of flue tubes

-

5

7

16

Water connections

-

Rp11/2

Rp11/2

Rp11/2

Gas connection

-

Rp3/4

Rp3/4

Rp3/4

Drain connection

-

3/4" - 14 NPT

3/4" - 14 NPT

3/4" - 14 NPT

Anode

-

3/4" - 14 NPT

3/4" - 14 NPT

3/4" - 14 NPT

Connection T&P-plug**

-

1” - 14 NPT

1” - 14 NPT

1” - 14 NPT

Maximum working heat

bar

8

8

8

Empty weight

kg

270

290

350

1.3.2 Technical data

Heater category:II

2H3+

* Gas usage at 1013,25 mbar and 15 °C.
** For a leak-tight connection European coupling pieces with pipe screw-thread according to ISO 228/1 or ISO 7/1 can be

used on the NPT-connection nipples.

This manual is related to the following products: