beautypg.com

A.O. Smith BFM 80 User Manual

Page 29

background image

29

yes

yes

yes

yes

yes

yes

yes

yes

no

no

no

no

no

no

no

Check

voltage present at

GATE 12 ECO

Check

voltage present at
GATE 11 BURNER

AUTOMATION

Pressure

H higher then

300 PA?

Pressure L less

then 0 PA?

Check

voltage present at

GATE 2 BURNER

AUTOMATION

Does the RESET

switch light up?

Check

voltage present at
GATE 10 BURNER

AUTOMATION

Ensure connections

correct, if yes replace

ECO

Ensure connections

correct

Measure pressure at

hose

H at the column

Ensure connections

correct, if yes

check hose H for

leakkage or blockings

Ensure connections

correct, if yes

check hose L for

leakkage or blockings

Check exhaust system on
blockings if the exhaust
system is open, replace AIR
PROVING SWITCH

Replace

BURNER AUTOMATION

Problem solved

Ensure connections

correct, if yes replace

RESET switch

RESET the water heater

and wait one cycle,

advanced Fault Finding