Kenwood RC-D710 User Manual
Page 11

5
Fuse holder
Fuse
■ Power Cable Connection (PG-5J)
Fixed Station
In order to use the PG-5J for fixed station operation, you will need a separate
13.8 V DC power supply that must be purchased separately.
Note: Do not plug the DC power supply into an AC outlet until you make all connections.
Mobile Installation
Be sure to use a 12 V vehicle battery that has sufficient current capacity. If the
current to the PG-5J is insufficient, the display may darken during transmission
or the transmit output power may drop excessively. Never connect the
transceiver to a 24 V battery.
Note: Install the PG-5J Interface Box using the included screw set in a location where it will
not interfere with driving.
■ Replacing Fuses (PG-5J)
If the fuse blows, determine the cause, then
correct the problem. After the problem is
resolved, replace the fuse. If newly installed
fuses continue to blow, disconnect the power
cable and contact your authorized Kenwood
dealer or an authorized Kenwood service center
for assistance.
Only use fuses of the specified type and rating; otherwise the PG-5J could be damaged.
Operation verifi cation models:
TM-V71, TM-D710, TM-D700, TM-V708, TM-G707, TM-V7, TM-733, TM-833,
TM-255, TM-455
• Using a 6-pin mini-DIN Data terminal, you can perform 1200/9600 data
communications. However, we do not guarantee the operation of the connected
transceiver.
• When connecting the transceiver other than described herein, there are times when
you must adjust the input/output levels between the RC-D710 and the transceiver.
• When the input/output levels of the connected transceiver cannot be adjusted, use the
MCP-2A Memory Control Program to adjust the RC-D710 input/output levels. Levels
can be adjusted in steps of 3dB.
When the output level from RC-D710 (PDK PIN) changes:
[Edit] - [Data Terminal] - [Output Level] - [PKD PIN (1200bps)]/ [PKD PIN (9600bps)]
When the input level to RC-D710 (PR9 PIN) changes:
[Edit] - [Data Terminal] - [Input Level] - [PR9 OUT (1200bps)]/ [PR9 OUT (9600bps)]
• To use the MCP-2A, you must use the PG-5G programming cable.