Operation – Hot Max Torches 250WFG User Manual
Page 11
Operation
KDAR Company
10
Controls—Arc
1. Power Level (Dial 3, Fugure 13)—Sets the power
level from 30-230 Amps. Power level can be ad-
justed while welding.
2. Welding Method Selector (Switch 4, Figure 13)—
Set rocker switch to the left setting for MIG weld-
ing.
Controls—MIG
1. Output Voltage Control (Dial 1, Figure 13)—The
Hot Max infinite setting output voltage control
knob adjusts to any setting from 13.7 to 28.5 volts.
2. Speed Control (Dial 2, Figure 13)—Controls the
wire feed speed.
3. Power Level (Dial 3,Figure 13)—Sets the power
level from 50-250 Amps. Power level can be ad-
justed while welding.
4. Welding Method Selector (Switch 4, Figure 13)—
Set rocker switch to the center setting for MIG
welding.
5. Gun Selector (Switch 5, Figure 13)—Used to se-
lect between standard MIG Gun and optional spool
gun.
6. Welding Method Indicator (LED 6, Figure 13)—
LED identifies which welding method is currently
selected.
Controls—TIG
1. Welding Method Selector (Switch 4, Figure 13)—
Set rocker switch to the center setting for MIG
welding.
2. Power Level (Dial 7, Figure 14)—Sets the power
level from 20-230 Amps.
Figure 12
Figure 13
1
2
On/
Off
3
4
5
6
7
Figure 14