VT Series 2
User Manual
Page 15
Videoswitch
VT601c.doc
remembered by the receiver (5 seconds minimum, to a resolution of 5 seconds) and used as the patrol
dwell time.
Before setting the time you must set AUX2 Off.
To start the timer press:
[SET], [LAMP] and [AUTOPAN]
After the required time has elapsed, stop the timer by pressing:
[SET], [LAMP] and [WIPE]
7.11 Alarm Patrol Timer
The alarm patrol dwell timer is set by issuing a command to start a timer, then issuing another command to
stop it. The amount of time that is allowed to elapse between the start and stop commands is remembered
by the receiver (5 seconds minimum, to a resolution of 5 seconds) and used as the patrol dwell time.
Before setting the time you must set AUX2 On.
To start the timer press:
[SET], [LAMP] and [AUTOPAN]
After the required time has elapsed, stop the timer by pressing:
[SET], [LAMP] and [WIPE]
7.12 Set Presets
Up to eight different presets may be set from the transmitter for each receiver in the system. To set a
preset, first move the selected camera to the required position and adjust the zoom, iris (if not auto) and
focus. This preset position may now be stored by pressing the following keys:
[SET], [LAMP] and [Preset 1, 2, 3, 4, 5, 6, 7 or 8]